SYMPTOMS
When you tried to deploy task sequence with captured image to a Windows XP machine using Operating System Deployment feature in System Center 2012 R2 Configuration Manager, the deployment fails and you may found the following error in smsts.log file:
CreateProcess failed. Code(0x800700C1) TSManager datetime 3048 (0x0BE8)
Command line execution failed (800700C1) TSManager datetime 3048 (0x0BE8)
Failed to install boot image.
is not a valid Win32 application. (Error: 800700C1; Source: Windows) TSManager datetime 3048 (0x0BE8)
Failed to install boot image CCR00004.
is not a valid Win32 application. (Error: 800700C1; Source: Windows) TSManager datetime 3048 (0x0BE8)
Failed to reboot the system. Error 0x(800700c1) TSManager datetime 3048 (0x0BE8)
Failed to initialize a system reboot.
is not a valid Win32 application. (Error: 800700C1; Source: Windows) TSManager datetime 3048 (0x0BE8)
Fatal error is returned in check for reboot request of the action (Restart in Windows PE).
is not a valid Win32 application. (Error: 800700C1; Source: Windows) TSManager datetime 3048 (0x0BE8)
Solution
To solve this issue install HOTFIX from KB2910552 on the following:
- Central Administration sites.
- Primary sites.
- Administrator consoles.
- Clients (Client update package will be created after installing hotfix on site system server).
Finally don’t forget to update Windows PE 3.1 boot images.